Working Hours: 24/7 National Service Hotline
NEWS CENTER
Real-time dynamics
Uniquely ingenious craftsmanship
Poetic Harmony
Second Public Notice for the Bidding of the Annual Inspection Project for Gas Detectors at Tianyuan Building
Visits:
74
Tender Documents
Hangzhou Tianyuan Building Co., Ltd. is conducting an open tender for the “Annual Inspection Project of Gas Detectors at Tianyuan Building.” Details are as follows:
1 Tender No.: TYDS-2023-016
2 Project Name: Hangzhou Tianyuan Building Gas Alarm Detector Inspection Project
3 Project Overview: To... Conduct annual inspections of gas detectors in areas such as building gas pipelines and kitchens.
4 Funding source: Self-funded with own capital.
5 Construction period requirements: No more than 20 days shall elapse from the date of contract signing.
6 Contracting Method and Scope of Contract:
(1) Lump-sum construction contract: covers labor, materials, quality, schedule, and safe and civilized construction.
(2) Scope of Contract: Gas alarm system within the building
7 Specific construction requirements: Complete Annual inspection of gas detectors in areas such as building gas pipelines and kitchens. , And issue a qualified testing report (which must be recognized by the relevant industry). Replace or repair any alarm devices that fail to meet the standards.
8 Qualification requirements that eligible bidders must meet:
(1) Bidders shall be registered within the territory of the People’s Republic of China.
(2) Possess relevant industry qualifications
(3) This project does not accept bids submitted by joint ventures.
9 · Engineering quality requirements: Construction shall be carried out strictly in accordance with the current national construction and acceptance specifications, quality inspection and evaluation standards, relevant documents issued by the national industry authorities guiding engineering construction, and the contents of the tender documents. The quality of the project must meet the standards specified in the "Code for Acceptance of Construction Quality" and the GB 50016-2006 Code for Fire Protection Design of Buildings. The warranty period for quality assurance is one year.
10 Material Brand Requirements : Existing brand
11 Construction site inspection time: On-site inspections will not be conducted in a unified manner; each bidding unit will conduct its own inspections.
12、 There will be no centralized Q&A session prior to bidding. Any questions from bidders will be answered by the procuring entity and provided in a unified written response.
13 Tendering method: Open tendering
14. Registration Period:
(1) Time: 2024 _01 Moon 06 As of 2024 01 _Month _10 Closed on Sundays (working hours: 9:00 a.m. to 11:30 a.m. and 2:00 p.m. to 4:30 p.m.).
(2) Location: Engineering Department, Tianyuan Building, No. 2 Qianchao Road, Hangzhou City
(3) Provide a copy of the business license of the corporate entity, a letter of authorization from the legal representative, photocopies of the ID cards of the legal representative and participating personnel, confirmation of the tender documents (with the official seal of the unit affixed to the tender documents), and a quotation table for comprehensive unit prices, among other documents.
15 Bid opening time: 2:30 p.m. on January 12, 2024
16 Composition of the Bid Evaluation Committee: An odd number of five or more people.
17 Evaluation Method: Comprehensive Bid Evaluation
18、 Maximum price: None
19 Contact information:
Tendering Entity: Hangzhou Tianyuan Building Co., Ltd.
Contact: Yang Yungang (13867495789)
Hangzhou Tianyuan Building Co., Ltd.
2024 January 6th of the year
Bid Evaluation Items
|
Serial number |
Comment Review Inside Capacity |
Score |
Scoring Criteria |
|
1 |
Equipment Inspection Quotation |
50 |
The lowest bidder ranks first; the highest score is... 60 Decreasing sequentially 10 Share |
|
2 |
Provide a list of testing equipment; if any equipment fails inspection, the unit price for replacement or repair will be specified. |
20 |
There's a list available. 5 Part, the lowest unit price for maintenance is required. 15 Decreasing sequentially 5 Share |
|
3 |
Business license, industry qualifications, |
5 |
There is. 5 Points—no score is not allowed. |
|
4 |
Commitment to follow-up measures in case of repair quality issues arising from equipment replacement |
10 |
Fully responsive 10 Points, partial credit awarded. 1-8 Share |
|
5 |
Unit Performance |
5 |
Contract provided for cooperation cases of comparable scale to this unit, 1 Home 1 Points—no points if not awarded. |
|
6 |
Other services and offers available |
10 |
Fully responsive 10 Points, partial credit awarded. 1-8 Share |
Relevant updates